ACOUSTIC INSTRUMENTS
Two SIMRAD scientific echo sounders, 38 and 120 kHz, were used during the survey for estimation of fish density. In addition an Es 400 split beam sounder was used.
|
INSTRUMENT SETTINGS |
|||
|
|
EK 400/38 |
EK 400/120 |
ES 400 |
|
Range |
0-100 or 0-250 |
0-100 |
0-25 to 0-250 |
|
Trans. |
High (5000 W NOM) |
High (1250 W NOM) |
EK/ES adapter |
|
Bandwidth |
3.3 kHz |
3.3 kHz |
3.5 kHz |
|
Pulslength |
1 ms |
1 ms |
1 ms |
|
TVG |
20 log R |
20 log R |
40 log R |
|
Attenuator |
20 dB |
0 |
Fixed |
|
Rec. gain |
7 |
5 |
|
|
Transducer |
8° × 8° ceramic or split beam |
Ceramic |
Split beam 10° |
Presentation mode: Compensated
EK 400/38 was coupled to the digital integrator QD and to one analog integrator QM.
|
QD settings: |
Gain 30dB, Threshold 10 to 26 mv. |
|
QM settings: |
Gain 20 dB x 10. Threshold 10. |
ES 400 was connected to an Epson printer for hardcopy of the size distribution diagram (histogram).
Calibration on standard copper sphere.
|
|
|
Grand Canary 5.10 1986 |
Las Palmas 4.11 1986 |
|
EK 400/38 + split beam transduser: |
|
|
|
|
SL + VR |
= |
135.9 |
135.8 |
1360 MESH PELAGIC TRAWL